Uponor UK
Head Office
Uponor UK
The Pavillion
Blackmoor Lane
Watford Hertfordshiree
WD18 8GA

Prefabricated systems

84 Results found

Uponor Combi Port M-Base HeatInterface RC

RC version for domestic hot water and direct heating with radiator connection (no mixing circuit). Mixing circuit can be upgraded by using the dedicated cabinet with installed UFH mixing group (Uponor Combi Port M-Base Cabinet+manif IW-UFH). Bypass function can be upgraded by using special accessory - Uponor Combi Port M-Base Heat Bypass.
Dimensioning codes:
15,19 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
ZV – zone valve in residential heating circuit return line without actuator
NI – no pipe insulation and/or insulated cover

Uponor Combi Port M-Base Cabinet+manif IW-UFH

In-wall mounted cabinet including feet, heating manifold, and rail with pre-installed ball valves and mixing circuit for extension of the Uponor Combi Port M-Base HeatInterface RC to UFH version.
Dimensioning codes:
HMV – set of Vario-S manifolds for heating with _ (4,6,8) heating circuits
BV – set of 7 ball valves pre-installed on the mounting rail inside the cabinet for heat interface connections
MS – mixing set with heating pump, thermostat, and non-return valve for apartment heating circuit

Uponor Combi Port M-BaseX HeatInterface IH

IH version for domestic hot water and indirect heating systems using second heat exchanger with heating circuit connections including heating pump and expansion tank mounted on the back of heat interface unit.
Dimensioning codes:
15, 21, 27 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
6D – all system connections in the bottom of heat interface unit
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
ZV – zone valve in residential heating circuit return line without actuator
ZH – apartment heating circuit circulation arrangement, including circulation pump, thermostatic flow controller and expansion tank
CR – heat interface metal cover casing white powder coated (RAL 9016)
NI – no pipe insulation and/or insulated cover
NC – no cold water outlet from heat interface unit

Uponor Combi Port M-BaseX Rail+valves bottom

Bottom mounting rail including set of preinstalled ball valves for 6D execution of heat interface unit
Dimensioning codes:
x6 – quantity of ball valves included in set (6 pcs)
DN20 – ball valve size
MT – male thread connection
FT – female thread connection

Uponor Combi Port M-Pro HeatInterface UFH

UFH version for domestic hot water and direct heating with underfloor heating connection (including mixing circuit with heating pump).
Dimensioning codes:
15,19 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
St – free of non-ferrous metal brazed stainless steel heat exchanger for domestic hot water preparation
BP – supply lines preheating function
DT – differential pressure controller at the heat interface unit heat circuit for domestic hot water preparation
ZM - circulation module for domestic hot water with safety valve, circulation pump, and differential pressure regulator. A waste water connection is needed.
MS – mixing set with heating pump, thermostat, and non-return valve for apartment heating circuit
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
UL – thermostatic temperature limiter for underfloor heating circuit
SS – safety thermostatic switch for apartment heating circuit
ZA - zone valve in residential heating circuit return line with 2-point actuator included
2C – second direct heating circuit connections with extra zone valve (no actuator, no mixing circuit)

Uponor Combi Port M-Pro HeatInterface RC

RC version for domestic hot water and direct heating with radiator connection (no mixing circuit).
Dimensioning codes:
15,19 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
St – free of non-ferrous metal brazed stainless steel heat exchanger for domestic hot water preparation
BP – supply lines preheating function
DI – primary differential pressure controller at the heat interface unit inlet
DT – differential pressure controller at the heat interface unit heat circuit for domestic hot water preparation
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
RL – return temperature limiter for apartment heating circuit
ZM – circulation module for domestic hot water with safety valve, circulation pump, and differential pressure regulator. A waste water connection is needed.
ZV – zone valve in residential heating circuit return line without actuator

Uponor Combi Port M-Pro Cabinet+manif IW

In-wall mounted cabinet including feet, heating manifold, and rail with pre-installed ball valves. Not needed circuits need to be plugged on site.
Dimensioning codes:
HMV – set of Vario-S manifolds for heating with _ (4,6,8,10) heating circuits
BV – set of 9 ball valves pre-installed on the mounting rail inside the cabinet for heat interface connections

Uponor Combi Port M-Pro Cabinet+manif OW

On-wall mounted cabinet including heating manifold, and rail with pre-installed ball valves. Not needed circuits need to be plugged on site.
Dimensioning codes:
HMV – set of Vario-S manifolds for heating with _ (4,6,8,10) heating circuits
BV – set of 9 ball valves pre-installed on the mounting rail inside the cabinet for heat interface connections

Uponor Combi Port M-Pro Cabinet IW

In-wall mounted cabinet including feet

Uponor Combi Port M-Pro Cabinet OW

On-wall mounted cabinet including door

Uponor Combi Port M-Pro Rail+valves Bottom

Mounting rail including set of preinstalled ball valves
Dimensioning codes:
x7/x9 – quantity of ball valves included in set (7 or 9 pcs)
DN20 – ball valve size
MT – male thread connection
FT – female thread connection

Uponor Combi Port M-Pro Temp. Limiter 2HC

Supplied lose return temperature limiter for second heating circuit connections in UFH version (2HC)