Uponor Smatrix Base PRO room sensor RH style T-141 Bus flush

- room temperature and relative humidity sensor (flush mounted)
- protection class: IP30
- color: white RAL9016

Consisting of:
- Uponor Smatrix Base PRO room sensor+RH Style T-141 Bus
- mounting material

Uponor Smatrix Base PRO room sensor RH style T-141 Bus flush

Item details

Uponor Smatrix Base PRO room sensor RH style T-141 Bus flush

Documents

Quick Guide
23 KB1120133

Quick Guide Smatrix Base PRO (1120133)

Quick Guide
1 KB1120132

Quick Guide Smatrix Base PRO (1120132)

Installation and Operation Manual
2 KB1088247

Installation and Operation Manual Smatrix Base PRO R-147 KNX (1088247)

EU declaration of conformity
811 B1132746

Uponor DoC SMATRIX 1071651 INT (1132746)

Application information

Specification

-autobalancing optimizing energy use and comfort
-up to 6 room thermostats and 8 actuators (24V) per controller; 6 channel expansion module option (with M-140)
-pump and boiler relays
-valve and pump exercise

Smatrix Base Pro controller X-147 with optional touch screen I-147 and KNX option
-up to 16 controller in one system
-daisy chain wiring or star wiring (with M-141)
-optional: display of controller information and settings (with I-147)
-optional: BMS integration via KNX interface (with R-147 and I-147)

Comfort settings comprises (with I-147)
-temperature setback programs for each channel
-max/min temperature limitations and relative humidity control
-holiday settings and automatic summer/winter change
-room bypass function
-advance cooling settings and automatic summer/winter change
-trend visualization (set point vs. room temperature, etc.)
-accessories configuration
-room check function and system diagnostic

Smatrix Base Pro controller X-148 ModBus RTU

Read data points
-temperature: outdoor / room / floor
-humidity level
-status of: actuator / pump / boiler / general purpose input (GPI)
-connection status of thermostat
-dynamic heat curve offset in integrated heat pump
Read and write data points
-room setpoint
-min/max levels for: setpoint / floor temperature
-settings: comfort/eco and autobalancing on/off
-heating/cooling: state / offset
-cooling not allowed for a room
-integrated heat pump defrost state

Application

- wired room temperature control for radiant heating and cooling
- set point range: +5°C ... +35°C