Uponor UK
Head Office
Uponor UK
The Pavillion
Blackmoor Lane
Watford Hertfordshiree
WD18 8GA

Combi Port M-Pro

8 Results found

Uponor Combi Port M-Pro HeatInterface UFH

UFH version for domestic hot water and direct heating with underfloor heating connection (including mixing circuit with heating pump).
Dimensioning codes:
15,19 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
St – free of non-ferrous metal brazed stainless steel heat exchanger for domestic hot water preparation
BP – supply lines preheating function
DT – differential pressure controller at the heat interface unit heat circuit for domestic hot water preparation
ZM - circulation module for domestic hot water with safety valve, circulation pump, and differential pressure regulator. A waste water connection is needed.
MS – mixing set with heating pump, thermostat, and non-return valve for apartment heating circuit
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
UL – thermostatic temperature limiter for underfloor heating circuit
SS – safety thermostatic switch for apartment heating circuit
ZA - zone valve in residential heating circuit return line with 2-point actuator included
2C – second direct heating circuit connections with extra zone valve (no actuator, no mixing circuit)

Uponor Combi Port M-Pro HeatInterface RC

RC version for domestic hot water and direct heating with radiator connection (no mixing circuit).
Dimensioning codes:
15,19 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
St – free of non-ferrous metal brazed stainless steel heat exchanger for domestic hot water preparation
BP – supply lines preheating function
DI – primary differential pressure controller at the heat interface unit inlet
DT – differential pressure controller at the heat interface unit heat circuit for domestic hot water preparation
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
RL – return temperature limiter for apartment heating circuit
ZM – circulation module for domestic hot water with safety valve, circulation pump, and differential pressure regulator. A waste water connection is needed.
ZV – zone valve in residential heating circuit return line without actuator

Uponor Combi Port M-Pro Cabinet+manif IW

In-wall mounted cabinet including feet, heating manifold, and rail with pre-installed ball valves. Not needed circuits need to be plugged on site.
Dimensioning codes:
HMV – set of Vario-S manifolds for heating with _ (4,6,8,10) heating circuits
BV – set of 9 ball valves pre-installed on the mounting rail inside the cabinet for heat interface connections

Uponor Combi Port M-Pro Cabinet+manif OW

On-wall mounted cabinet including heating manifold, and rail with pre-installed ball valves. Not needed circuits need to be plugged on site.
Dimensioning codes:
HMV – set of Vario-S manifolds for heating with _ (4,6,8,10) heating circuits
BV – set of 9 ball valves pre-installed on the mounting rail inside the cabinet for heat interface connections

Uponor Combi Port M-Pro Cabinet IW

In-wall mounted cabinet including feet

Uponor Combi Port M-Pro Cabinet OW

On-wall mounted cabinet including door

Uponor Combi Port M-Pro Rail+valves Bottom

Mounting rail including set of preinstalled ball valves
Dimensioning codes:
x7/x9 – quantity of ball valves included in set (7 or 9 pcs)
DN20 – ball valve size
MT – male thread connection
FT – female thread connection

Uponor Combi Port M-Pro Temp. Limiter 2HC

Supplied lose return temperature limiter for second heating circuit connections in UFH version (2HC)