Uponor S-Press PLUS tee female thread 16-Rp1/2"FT-16
Uponor S-Press PLUS tee female thread 20-Rp1/2"FT-20
Uponor S-Press PLUS tee female thread 20-Rp3/4"FT-20
Uponor S-Press PLUS tee female thread 25-Rp1/2"FT-25
Uponor S-Press PLUS tee female thread 25-Rp3/4"FT-25
Uponor S-Press PLUS tee female thread 32-Rp1/2"FT-32
Uponor S-Press PLUS tee female thread 32-Rp3/4"FT-32

Documents

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Installation Report
110 B1120118

Installation Report MLC leak test report TW air-gas (1120118)

Application information

Specification

- Unique press indicator
- Fast 3-step installation (press without bevel)
- Innovative QR code for immediate digital access
- Colour code
- Fixed press sleeve with insprection window
- Precise jaw fixation
- Fast diameter recognition
- Accurate test safety function
- 100% backward compatible with existing Uponor components
- Flow rate optimized fitting body

Application

- Tap water: The permanent operating temperature ranges from 0°C to 70°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 95°C for a period of 100 hours in the operating life time.
- Heating: The permanent operating temperature ranges up to 80°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 100°C for a period of 100 hours in the operating life time.

if not different mentioned:
- Male and female threads acc.to EN 10226-1.

Certification

- Approvals by local OM.
E.g.
- DVGW
- AENOR

Product drawings

1070595_LAB
1070595
79 B
1070596_LAB
1070596
79 B
1070597_LAB
1070597
79 B
1070598_LAB
1070598
79 B
1070599_LAB
1070599
79 B
1070600_LAB
1070600
79 B
1070601_LAB
1070601
79 B
1070595_ZMD
1070595
171 B
1070596_ZMD
1070596
171 B
1070597_ZMD
1070597
171 B
1070598_ZMD
1070598
171 B
1070599_ZMD
1070599
171 B
1070600_ZMD
1070600
171 B
1070601_ZMD
1070601
171 B
1070595_REN
1070595
415 B
1070595_REN
1070595
259 B
1070596_REN
1070596
46 B
1070597_REN
1070597
48 B
1070598_REN
1070598
44 B
1070599_REN
1070599
46 B
1070600_REN
1070600
47 B
1070601_REN
1070601
48 B