Uponor RS adapter S-Press

- Made of tin-plated brass
- Fits to all RS2 base parts.

Uponor RS adapter S-Press

Item details

Uponor RS adapter S-Press 16-RS2

Documents

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Installation Report
110 B1120118

Installation Report MLC leak test report TW air-gas (1120118)

DGNB Declaration
295 B1141468

UPONOR DGNB RS Fittings (1141468)

Application information

Specification

- with fixed press sleeve
- stop ring
- colour code
- Test safety

Application

- Tap water: The permanent operating temperature ranges from 0°C to 70°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 95°C for a period of 100 hours in the operating life time.
- Heating: The permanent operating temperature ranges up to 80°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 100°C for a period of 100 hours in the operating life time.

if not different mentioned:
- Male and female threads acc.to EN 10226-1.

Certification

- Approvals by local OM.
E.g.
- DVGW
- AENOR

Product drawings

0000028569_1059397_REN
0000028569
223 B
1059397_REN
1059397
76 B
1059397_ZMD
1059397
180 B