Uponor UK
Head Office
Uponor UK
The Pavillion
Blackmoor Lane
Watford Hertfordshiree
WD18 8GA

Uponor Combi Pipe opaque in conduit red

- Pipes manufactured from peroxide cross-linked polyethylene (PE-Xa) acc. EN ISO 15875
- EVOH (ethylene vinyl alcohol) layer for oxygen diffusion resistance as per DIN 4726
- Application class 2 - hot water supply
- Application class 4 - Underfloor heating and low tempertaure radiators
- Application class 5 - high temperature radiators
- Fire classification E according to DIN EN 13501-1
- Conduits manufactured from high density polyethylene
- Tap water: The permanent operating temperature ranges from 0°C to 70°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 95°C for a period of 100 hours in the operating life time.
- Underfloor heating and low tempertaure radiators
- Heating: The permanent operating temperature ranges up to 90°C at a maximum permanent opereting pressure of 6 bar. The short-term malfunction temperature is 100°C for a period of 100 hours in the operating life time.
- Leakage free installations with possibility to exchange pipes in case of damage

Uponor Combi Pipe opaque in conduit red

Item details

Uponor Combi Pipe opaque in conduit red 16x1,8 25/20 50m
Uponor Combi Pipe opaque in conduit red 20x1,9 28/23 50m
Uponor Combi Pipe opaque in conduit red 25x2,3 34/28 50m

Documents

Product Information
212 B1142160

PI PEX tap water heating UK 1142160

Technical information
1 KB1118689

Technical Information PE-Xa piping systems (1118689)

Approval Certificate
108 B1088311

Uponor CER Combi PIpe SYS MECH WRAS1607061 GB EN (1088311)

Environmental Product Declaration (EPD)
941 B1143845

Uponor EPD_ Combi Pipe in conduit (1143845)

Brochure
293 B1141479

UPONOR DGNB COMBI PeX-a Rohre (1141479)

About

Specification

- Pipes manufactured from peroxide cross-linked polyethylene (PE-Xa) acc. EN ISO 15875
- EVOH (ethylene vinyl alcohol) layer for oxygen diffusion resistance as per DIN 4726
- Application class 2 - hot water supply
- Application class 4 - Underfloor heating and low tempertaure radiators
- Application class 5 - high temperature radiators
- Fire classification E according to DIN EN 13501-1.

Application

- Tap water: The permanent operating temperature ranges from 0°C to 70°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 95°C for a period of 100 hours in the operating life time.
- Underfloor heating and low tempertaure radiators
- Heating: The permanent operating temperature ranges up to 90°C at a maximum permanent opereting pressure of 6 bar. The short-term malfunction temperature is 100°C for a period of 100 hours in the operating life time.

Product drawings

1059179_ZMD
1059179
203 B
1059180_ZMD
1059180
203 B
1059181_ZMD
1059181
203 B
1059179_REN
1059179
117 B
1059179_REN
1059179
119 B
1059180_REN
1059180
119 B
1059181_REN
1059181
119 B
1059179_LAB
1059179
109 B
1059180_LAB
1059180
109 B
1059181_LAB
1059181
109 B