Uponor UK
Head Office
Uponor UK
The Pavillion
Blackmoor Lane
Watford Hertfordshiree
WD18 8GA

Uponor S-Press adapter male thread

- Made of tin-plated brass
- Fast installation with easy bevel and without calibration
- Colour code

Uponor S-Press adapter male thread

Item details

Uponor S-Press adapter male thread 40-R1 1/4"MT
Uponor S-Press adapter male thread 40-R1 1/2"MT
Uponor S-Press adapter male thread 50-R1 1/2"MT
Uponor S-Press adapter male thread 50-R2"MT
Uponor S-Press adapter male thread 63-R2"MT
Uponor S-Press adapter male thread 75-R2 1/2"MT

Documents

Product Information
259 B1142159

PI MLC tap water heating UK 1142159

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Approval Certificate
836 B1089107

UPONOR CER MLC SYS MECH Lloyds Register 17-20013-2 GB EN (1089107)

Approval Certificate
409 B1013450

UPONOR SAMPLE MLC PIPE WHITE 50X4,5 LENGTH 30CM

Approval Certificate
409 B1013402

UPONOR SAMPLE MLC PIPE WHITE 32X3 LENGTH 30CM (1013402)

About

Specification

- with fixed press sleeve
- stop ring
- test safety

Application

-Heating systems (high temperature radiators) - where the water temperature does not continuously exceed 80ºC, 10 bar (Conditions to application Class 5 - BS EN ISO 21003-1:2008). The maximum short-term malfunction temperature is 100ºC for an accumulative 100 hours over the working life of the system. (Heating systems must be installed with room and water temperature controls in accordance with the current Building Regulations Parts L1 (Energy – Dwellings) and L2 (Energy – Non Dwellings) for England and Wales, or an equivalent national standard for Scotland or Republic of Ireland)
-Cold water domestic services: 0°C to 20°C where the water temperature does not exceed 20ºC, 16bar
-Hot water domestic services: 20°C to 70°C where the water temperature does not continuously exceed 70ºC, 10 bar (Conditions to application Class 2 - BS EN ISO 21003-1:2008). The maximum short-term malfunction temperature is 95ºC for an accumulative 100 hours over the working life of the system.
-Uponor multi-layer pipe can be used for DHW recirculating systems, provided the operating temperatures and pressures do not exceed the maximum conditions detailed under 'Domestic Services'
-Chilled water: -10°C to 10°C,10 bar. If risk of damage from freezing, a suitable anti-freeze additive must be used. Any additive must be suitable for use with Polyethylene, PPSU, EPDM and CW625N brass
if not different mentioned:
- Male and female threads acc.to EN 10226-1.

Certification

-WRAS : 2010907 - Uponor S-Press 12 & 14mm, MLC
-WRAS : 2109108 - S-Press & RS Modular 40-110mm, MLC
-KIWA – UK water Regulation 4
-Manufacturing is in accordance with the international quality standard ISO 9001 and environmental standard ISO 14001

Product drawings

1032895_REN
1032895
389 B
1032896_REN
1032896
136 B
1046901_REN
1046901
389 B
1046901_REN
1046901
136 B
1046902_REN
1046902
165 B
1046905_REN
1046905
35 B
1032896_ZMD
1032896
132 B
1046901_ZMD
1046901
132 B
1046902_ZMD
1046902
132 B
1046905_ZMD
1046905
132 B
1032896_LAB
1032896
115 B
1046901_LAB
1046901
115 B
1046902_LAB
1046902
115 B
1046905_LAB
1046905
115 B