Uponor International Sales
Industriestrasse 56, 97437 Hassfurt, Germany

Uponor S-Press elbow male thread

- Made of tin-plated brass
- Fast installation with easy bevel and without calibration
- Colour code

Uponor S-Press elbow male thread

Item details

Uponor S-Press elbow male thread 40-R1 1/4"MT

Documents

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Installation Report
110 B1120118

Installation Report MLC leak test report TW air-gas (1120118)

Application information

Specification

- with fixed press sleeve
- stop ring
- test safety

Application

- Tap water: The permanent operating temperature ranges from 0°C to 70°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 95°C for a period of 100 hours in the operating life time.

- Heating: The permanent operating temperature ranges up to 80°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 100°C for a period of 100 hours in the operating life time.

- if not different mentioned:
Male and female threads acc.to EN 10226-1.

Certification

- Approvals by local OM.
E.g.
- DVGW
- AENOR

Product drawings

1046909_REN
1046909
339 B
1046909_REN
1046909
85 B
1046909_ZMD
1046909
71 B