Slab sensor 10k

For use with Uponor radiant heating system thermostats, including the Climate Control Zoning System II Wireless Digital Thermostat (T-167) (part number A3800167) and the Uponor Heat-only Thermostat with Touchscreen (part number A3100101), the Uponor Slab Sensor, 10k (part number A9010599) senses the slab or floor temperature in radiant floor heating systems and provides temperature limit protection.

Thermal mixing valves

Thermal mixing valves thermostatically control water temperature ranges between 80°F (26.7°C) and 165°F (73.9°C). The non-corrosive reactive valves feature 1" nominal sweat union connections and a Cv of 2.52.

Thermal zone valves

Thermal zone valves (24 VAC) feature 34" and 1" sweat connections. They provide flow control for single-zoned manifolds (manifolds serving one zone). The valves include an end switch for activation of a relay (pump), heat plant or other auxiliary devices.

Three-way mixing valves

Three-way mixing valves are microprocessor-controlled valves designed to regulate supply-water temperatures to radiant heating systems by modulating the position of the valve. Configure mixed supply water temperature to reset (or vary) based on the outdoor temperature or control to a fixed, constant temperature. Use optional boiler sensor to provide protection in non-condensing boiler applications.

Two-wire thermal actuators for EP Heating Manifolds

Two-wire, slow-opening thermal actuators mount directly onto EP heating manifolds to provide individual-loop flow control on a multi-zoned manifold (a manifold serving more than one zone). Note: See actuator-to-manifold compatibility table on page 96.

Two-wire thermal actuators for Stainless-steel Manifolds

Two-wire, slow-opening thermal actuators mount directly onto stainless-steel heating manifolds to provide individual-loop flow control on a multi-zoned manifold (a manifold serving more than one zone). Note: See actuator-to-manifold compatibility table on page 96.

Two-wire thermal actuators for TruFLOW Classic and Jr. Valved Manifolds

Two-wire, slow-opening thermal actuators mount directly onto TruFLOW Classic and TruFLOW Jr. valved heating manifolds to provide individual-loop flow control on a multi-zoned manifold (a manifold serving more than one zone). Note: See actuator-to-manifold compatibility table on page 96.

Wireless base unit

Wireless base units support up to six thermostats and eight actuators (sold separately). The units receive information from the thermostats to open and close the connected actuator(s) and control the flow of water through the loops of PEX tubing in radiant heating systems or supply lines for baseboard applications. The units come with an antenna that mounts directly to the case along with a cable that can be used to remote mount the antenna outside of a metal manifold cabinet. They require 24 VAC for power which can be supplied using the A3500050 50VA transformer. Mounting hardware is included.Note: Not compatible with previous A360 Climate Control Zoning System products.

Wireless dial thermostats

Wireless dial thermostats provide total freedom of thermostat placement to ensure the best control of a radiant heating system. The thermostat can send a demand for heating up to 98 ft. to a wireless base unit (through normal construction). The thermostat includes a blue ring around the dial that illuminates when the set temperature is adjusted. An orange LED will illuminate when there is an active heating demand or a low-battery status. Setpoint temperature range is adjustable from 41°F (5°C) to 96°F (35.6°C), and default temperature is 68°F (20°C). The thermostat uses two standard AAA batteries (included). Note: Not compatible with previous A360 Climate Control Zoning System products.

Wireless digital thermostats

Wireless digital thermostats provide total freedom of thermostat placement to ensure the best control of a radiant heating system. The thermostat can send a demand for heating up to 98 ft. to a wireless base unit (through normal construction). The back-lit digital display can be configured to Fahrenheit (°F) or Celsius (°C) and shows when the area is actively heating. The thermostat's setpoint temperature range is adjustable from 41°F (5°C) to 96°F (35.6°C) and it can be used with an optional floor sensor (sold separately). It uses two standard AAA batteries (included) and features a low-battery status. Note: Not compatible with previous A360 Climate Control Zoning System products.

Wireless expansion module

Wireless base unit expansion modules easily connect to wireless base units to add an additional six thermostats and six actuators (for a total of 12 thermostats and 14 actuators in the system).Tip: The antenna will need to be disconnected and reinstalled on the expansion module when expanding the number of zones.Note: Not compatible with previous A360 Climate Control Zoning System products.

Zone control modules

Zone control modules provide connection between thermostats and their respective actuators or zone valves as well as the connection between the end switches and the pump or boiler relay. They are compatible for use with all two-wire and four-wire Uponor actuators. The modules are internally fused for protection from over current or direct shorts from the power supply transformer. The end switch circuit is also protected from over current, and a two-amp fuse is factory installed.